hi all.
I want to ask if anybody implemented a variable coupling between RF amp and detector? Is it needed? what is the best way ? and so on.
Thanks


Top
 Profile  
 
PostPosted: Fri Mar 02, 2012 10:35 pm 
Offline

Joined: Sun Dec 02, 2007 7:50 am
Posts: 1005
Piter_ wrote:
hi all.
I want to ask if anybody implemented a variable coupling between RF amp and detector?


Are we talking about a regen set or a TRF or what?

Piter_ wrote:
Is it needed?


If this is in a Regen set and the RF amp is providing the "isolation" in order to prevent the antenna Loading the detector, then NO the variable coupling is not needed!(not to prevent loading by the antenna)

If the purpose of the "variable coupling" is for the purpose of controlling bandwidth/selectivity(and not to prevent "loading") then maybe it is needed(or just desirable not actually needed).

Piter_ wrote:
what is the best way ? and so on.
Thanks


Without knowing more about what you are trying to achieve, in what type of set, I cant really provide any other answers.

73
kb0lxy


Top
 Profile  
 
 Post subject:
PostPosted: Sat Mar 03, 2012 3:08 am 
Offline

Joined: Sun Nov 02, 2008 7:15 am
Posts: 430
Location: NJ, USA
It would certainly help to know the application and what you are trying to achieve. If it is a regen with RF buffer/amp then normally an attenuator is added at the RF stage input instead of variable RF stage to detector coupling.


Top
 Profile  
 
 Post subject:
PostPosted: Sat Mar 03, 2012 3:59 am 
Offline

Joined: Sun Feb 28, 2010 2:12 pm
Posts: 1021
Not a tube desgn, but here's a Charles Kitchin FET design that implements variable coupling of the RF stage to the detector.

http://www.arrl.org/files/file/Technolo ... hb1768.pdf

I believe Mr. Kitchin later said that while variable detector loading was the best approach for highest (potential) selectivity, this was very difficult to do properly because the physical presence of the variable loading capacitor and the wires will load down the detector. He proposes as an alternative light fixed coupling of RF amp to detector and variable RF attenuation ahead of the RF amp.

Here are some links where he discusses the issue:
http://groups.yahoo.com/group/regenrx/message/5402
http://www.archive.org/details/Updating ... veCircuits
http://www.archive.org/compress/Masscon ... eedingsiso


Top
 Profile  
 
 Post subject:
PostPosted: Sun Mar 04, 2012 6:37 pm 
Offline

Joined: Wed Jan 21, 2009 11:39 am
Posts: 212
I am talking about regen receiver.
Thanks to all. The last post answers my question.


Top
 Profile  
 
Display posts from previous:  Sort by  
Post new topic Reply to topic  [ 5 posts ] 

All times are UTC


Who is online

Users browsing this forum: No registered users and 0 guests


You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot post attachments in this forum

Search for:
Jump to:  
Powered by phpBB® Forum Software © phpBB Group